INW side channel blowers and exhausters
DOUBLE STAGE
Double stage ring blowers/exhausters INW can be applied as vacuum pump and compressor in continuous operation over the total stated performance curve range. The motors are available as standard for the input voltage range of 50 and 60 Hz and for protection category IP 54 (protection against dust and splashing water). Ring blowers/exhausters INW conform to the European Community's Machinery Directive (CE) and they also meet Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substance in electrical and electronic equipment.
Motors are designed according to the DIN EN 60 034/ IEC 34-1 and temperature class F. For the three phase machines the tolerance +/- 10% for fixed voltage and for +/- 5% voltage range. The double phase machines are designed with a +/- 5% tolerance. If only 90% of the maximum allowed pressure will be used for continuous operating then the allowed voltage range add to +/- 10%. The frequency tolerance is maximum +/- 2%.
INW double stage blowers and exhausters
![]() |
|
![]() |
![]() |
PDF document 366 kB INW double stage side channel blowers - curves for vacuum |
PDF document 366 kB INW double stage side channel blowers - curves for pressure |
| Type | Suction
(m3/h) |
Pressure/ vacuum (mbar) |
Motor (IP54) |
Noisi -ness (dB) |
Weight (kg) |
Connection | ||
| 50 Hz |
Voltage | Current | ||||||
| (kW) | (V) | (A) | ||||||
| THREE PHASES |
||||||||
| INW 220 H26 |
85 | 240/210 | 0,7 | 200-240 Δ/380-415 Y |
3,8 Δ/2,2 Y |
55 | 17 | G 1¼" |
| INW 420 H36 |
150 | 280/280 | 1,6 | 200-240 Δ/380-415 Y | 7,5 Δ/4,3 Y |
66 | 28 | G 1½" |
| INW 420 H46 |
150 | 440/330 | 2,2 | 200-240 Δ/380-415 Y | 9,7 Δ/5,6 Y |
66 | 31 | G 1½" |
| INW 520 H46 |
230 | 410/340 | 3 | 200-240 Δ/380-415 Y | 12,5 Δ/7,2 Y |
72 | 46 | G 2" |
| INW 520 H57 |
230 | 490/390 | 4 | 380-415 Δ |
10 Δ/5,8 Y |
72 | 48 | G 2" |
| INW 720 H16 |
320 | 210/220 | 2,2 | 200-240 Δ/380-415 Y | 9,7 Δ/5,6 Y |
73 | 48 | G 2" |
| INW 720 H26 |
320 | 260/280 | 3 | 200-240 Δ/380-415 Y | 12,5 Δ/7,2 Y |
73 | 55 | G 2" |
| INW 720 H37 | 320 | 380/360 | 4,3 | 380-415 Δ | 10 Δ/5,2 Y |
73 | 62 | G 2" |
| INW 720 H47 |
320 | 500/440 | 5,5 | 380-415 Δ | 13,3 Δ/7,7 Y |
73 | 78 | G 2" |
| INW 720 H57 |
320 | 570/440 | 7,5 | 380-415 Δ | 16,7 Δ/9,6 Y |
73 | 80 | G 2" |
| INW 820 H17 |
520 | 240/240 | 5,5 | 345-415 Δ/600-720V Y | 13,3 Δ/7,7 Y | 74 | 95 | G 2½" |
| INW 820 H27 | 520 | 400/400 | 7,5 | 345-415 Δ/600-720V Y | 16,7 Δ/9,6 Y | 74 | 100 | G 2½" |
| INW 820 H37 | 520 | 600/430 | 11 | 345-415 Δ/600-720V Y | 28,0 Δ/16,2 Y | 74 | 130 | G 2½" |
| INW 820 H47 | 520 | 670/460 | 15 | 345-415 Δ/600-720V Y | 32,5 Δ/18,8 Y | 74 | 140 | G 2½" |
| INW 920 H17 | 1110 | 270/300 | 12,5 | 345-415 Δ/600-720V Y | 28,0 Δ/16,2 Y | 74 | 185 | DN100 |
| INW 920 H27 | 1110 | 370/420 | 16,5 | 345-415 Δ/600-720V Y | 35,0 Δ/20,0 Y | 74 | 190 | DN100 |
| INW 920 H37 | 1110 | 500/440 | 20 | 345-415 Δ/600-720V Y | 40,0 Δ/23,0 Y | 74 | 200 | DN100 |
| INW 920 H47 | 1110 | 590/450 | 25 | 345-415 Δ/600-720V Y | 52,0 Δ/30,0 Y | 74 | 220 | DN100 |
| SINGLE PHASE | ||||||||
| INW 220 A21 |
88 | 220/190 | 0,7 | 200-240 | 4,5 | 55 | 17 | G 1¼" |
| INW 420 A31 |
150 | 260/260 | 1,3 | 200-240 | 9 | 66 |
32 |
G 1½" |
![]() |
INW blowers/exhausters meet Directive 2002/95/EC of European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment. |
INW blowers/exhausters conform to the European Community‘s Machinery Directive (CE). |
We also offer high pressure blowers/exhausters INW-HP.
If you are interested in price offer, please, fill in our inquiry form.
BLOWERS diaphragmatic side channel roots EXHAUSTERS diaphragmatic side channel ACCESSORIES Aeration membrane filters, safety valves and manometers for blowers filters, safety valves and manometers for exhausters noise covers FLOWMETERS small flow rates medium flow rates large flow rates